Product

ProSeries 1

ProSeries 2

LXP Hybrid

LightningTM II Digital

Highlights

Enables high processing speeds for a broad range of applications.

Delivers high accuracy for applications requiring precision scanning.

Highest marking speed; self-tuning for highest system performance and efficiency.

Delivers highest processing accuracy and speed with 24-bit position resolution.

Wavelength Options

355 nm / 532 nm / 1030 nm - 1080 nm / 9.4 μm - 10.6 μm 
Broadband Coatings: 350 nm – 12 μm

Mirror Aperture

    7 mm | 10 mm | 14 mm

     7 mm | 10 mm | 14 mm

    7 mm | 10 mm | 14 mm

14 mm

Scan Angle

  ± 20° |  ± 22° | ± 22°

  ± 20° |   ± 22° | ± 22°

  ± 20° |  ± 22°  | ± 22°

± 22°

Typical Marking Speed1
(m/s)

  4.0 |   3.1    | 2.5

  3.5 |    2.9    | 1.7

  6.5 |    5.0   | 4.0

8

Typical Write Speed 1,2
(cps)

1100 |  1000 | 890

1000 |   650    | 550

1350 |  1100  | 950

N/A

Step Response3,4
(µsec)

  185 |   220  | 280

  230 |   340   | 360

  185 |   220  | 280

360

Repeatability5,6
(µrad)

  20 |    16    | 12

  15 |    15   | 12

  30 |    25   | 20

2

Command Resolution

16-bit

16-bit

16-bit

24-bit

Long Term Drift7,8

Offset: <200 µrad
Scale: <200 ppm

Offset: <100 µrad
Scale: <100 ppm

Offset: <200 µrad
Scale: <200 ppm

10 µrad

Thermal Drift

Offset: <25 µrad/°C
Scale: <50 ppm/°C

Offset: <20 µrad/°C
Scale: <50 ppm/°C

Offset: <25 µrad/°C
Scale: <50 ppm/°C

2 µrad

Modular or Enclosed

Enclosed

Enclosed

Enclosed

Modular

Datasheets ProSeries Scan Head | ProSeries 2 Large Aperture Scan Head | LXP Hybrid Scan Head | Lightning™ II Scan Head
Notes:

All angles are in optical degrees, unless otherwise noted.

1. 160 mm F-Theta lens used for marking and writing speed.

2. Single stroke 1 mm characters, SIMPLEX font.

3. For ProSeries and LXP scan heads: assumes steps size of 1% of full scale. 

4. For LightningTM II scan heads: assumes step size of 10 mrad.

5. For ProSeries and LXP scan heads: <3 sigma from mean, per axis.

6. For LightningTM II scan heads: RMS, per axis.

7. For ProSeries and LXP scan heads: During 24 hours of operation after 30 minutes of warm up, per axis.

8. For LightningTM II scan heads: During 8 hours of operation after 30 minutes of warm up, per axis.