Product | ProSeries 2 |
LightningTM II |
Highlights | Delivers high accuracy; ideal for large aperture applications. |
Delivers highest processing accuracy and speed; 24-bit position resolution. |
Wavelength Options | 355 nm / 532 nm / 1030 nm - 1080 nm / 9.4 μm - 10.6 μm |
|
Mirror Aperture | 20 mm | 25 mm |
20 mm | 25 mm | 27 mm | 30 mm |
Scan Angle | ± 20° | ± 15° |
± 20° | ± 17° | ± 18° | ± 22° |
Typical Processing Speed1 | 1.0 m/s | 0.9 m/s |
50 rad/sec |
Step Response2,3 (µsec) |
800 | 900 |
370 | 360 | 450 | 550 |
Command Resolution | 16-bit |
24-bit |
Repeatability4,5 (µrad) |
12 | 12 |
<1 |
Long Term Drift6,7 | Offset: <100 µrad |
10 µrad |
Thermal Drift | Offset: <20 µrad/°C |
2 µrad opt/°C |
Modular or Enclosed | Enclosed |
Modular |
Datasheets | ProSeries 2 Large Aperture Scan Heads | Lightning™ II Scan Heads | |
Notes: | All angles are in optical degrees, unless otherwise noted. 1. 160 mm F-Theta lens with single stroke 1 mm characters, SIMPLEX font 2. For ProSeries and LXP scan heads: assumes steps size of 1% of full scale. 3. For LightningTM II scan heads: assumes step size of 10 mrad. 4. For ProSeries and LXP scan heads: <3 sigma from mean, per axis. 5. For LightningTM II scan heads: RMS, per axis. 6. For ProSeries and LXP scan heads: During 24 hours of operation after 30 minutes of warm up, per axis. 7. For LightningTM II scan heads: During 8 hours of operation after 30 minutes of warm up, per axis. |